If the toe reflection signal is clearly visible, the reading should match the real length of the pile. For that purpose, calibration of the speed...
If the toe reflection signal is clearly visible, the reading should match the real length of the pile. For that purpose, calibration of the speed wave / velocity is required. Then the velocity will be changed to make the measured length to match with the expected length of the pile.
Proceq is now part of Screening Eagle Technologies. Screening Eagle is a merger of Dreamlab, a Singapore-based software and robotics company and Proceq, a Swiss-based NDT company with a 65+ year heritage as a market leader in portable sensors. Together, we protect the built world with software, sensors and data.